Interior Partitions Sample Clauses

Interior Partitions. New interior walls shall be constructed of 3-5/8” x 25 Ga. metal studs at 16” O/C with 1/2” gypsum wallboard on both sides. Walls shall extend to 6” above the ceiling grid, except full height at large Conference Room.
AutoNDA by SimpleDocs
Interior Partitions. Interior partitions shall be constructed with 3 5/8” x 20 gauge metal studs at 16” O.C. Walls are to extend 6” above adjacent ceilings with 5/8” gypsum wallboard placed on each side of studs. Gypsum wallboard shall be taped and finished with joint compound to a Level 4 finish, with the stud cavity being filled with sound attenuation insulation in partitions between offices. Where no ceilings occur, partitions to extend full height to underside of structure above.
Interior Partitions. Taped, finished and painted (two coats of flat latex, MAB or approved equal) partitioning to be constructed with one layer of 1/2” drywall mounted on each side of 3 1/2” metal studs.
Interior Partitions. Partitions shall be constructed of ------------------- metal stud and drywall or other similar forms of construction material in accordance with the Uniform Building Code. Non-rated partitions are allowed within the Premises and shall be installed by Tenant in accordance with building standards established by Landlord. Request for non-standard interior partitions shall be submitted to Landlord for Landlord's written approval. Partitions meeting the interior face of the glazed external Building wall or column shall terminate only at the centerline of window mullions or columns. Tenant shall install, to the extent the same have not already been installed, the studs for all demising walls separating Tenant's premises from other premises on multi- tenant floors. Tenant will be responsible for one-half (1/2) of the cost of installing the studs for Tenant's demising walls or, if Tenant is only required to install the studs for one (1) demising wall, Tenant shall be responsible for the entire cost of installation of such studs.
Interior Partitions. 1. 3 5/8” – gauge minimum stud thickness at 16” oc minimum.
Interior Partitions. All interior partitioning including the finishing thereof complete with millwork and fixtures.
Interior Partitions. 4.3.1 Interior partitions shall be as indicated on the plans, but primarily shall be metal and/or wood studs with gypsum board wall covering. Minimum construction shall be 2" x 4" or 2" x 6" blocking on 16" centers. Wood studs used in non-sprinklered areas (above finished ceiling) are not permissible unless concealed area is sprinklered.
AutoNDA by SimpleDocs
Interior Partitions. 3 5/8” X 25 Ga. metal studs at 24” on center with 5/8” Type ‘X’ gypsum board each side to the finished ceiling 9’-0”). Seismic bracing per City of Thousand Oaks Building Department. Gypsum board taped smooth to receive paint. Pertinent metal casing where applicable.
Interior Partitions. A. Partitions, except as otherwise indicated, shall be of 4" nominal stud construction with minimum 5/8" gypsum board on each side. Joints shall be taped or joined with acceptable mechanical joints to provide a continuous surface, suitable for a high-grade, durable finish. All newly constructed wall intersections in heavy traffic areas shall receive a "Bullnose" detail in treatment. (Corner guards are acceptable).
Interior Partitions. All interior partitions must be erected in accordance with the floor plan. The landlord shall review the typical floor plan and/or the space allocation to determine the offices requiring interior partitions. The location of private offices and auxiliary space requiring partitions to be constructed by the lessor will be determined by lessee in the final design phase of the project. Interior partitions shall be constructed as follows: